Scope of Services

Turnkey cleanroom, HVAC, equipment and MEP solutions.

Accord delivers the complete cleanroom, HVAC and MEP package under one roof, engineered around your process, manufactured in our own plant, installed and qualified by our teams.

Scope Breakdown

What sits inside each discipline

Mechanical (HVAC)

  • Air handling units
  • Dehumidification (DHU)
  • Chillers & CHW piping
  • GI / Al / SS ducting
  • HEPA terminal filtration
  • VFD & controls

Electrical

  • HVAC power panels & MCC
  • Control panels & PLC
  • GMP light fixtures
  • Cleanroom wiring & sockets
  • Earthing & safety systems

Plumbing & Utilities

  • Chilled / hot water piping
  • Drain & condensate lines
  • Insulated utility piping
  • Pump house & cooling towers
  • Compressed air distribution

Cleanroom Envelope

  • Modular wall panels
  • Walkable ceiling system
  • GMP doors & view panels
  • Epoxy / PU flooring
  • Pass boxes & air showers

Also within our scope

Consultancy & facility layout • cGMP validation (DQ / IQ / OQ) • laboratory furniture & cleanroom accessories • process & packaging equipment • gap analysis on existing facilities • documentation support for regulatory audits.

Engineering Design Basis

Classification we design and validate to

Facilities engineered to ISO 14644-1 and FS 209E, using turbulent-dilution or unidirectional airflow according to the risk in each room.

Cleanroom classification, maximum particle counts and typical air changes per hour
ISO 14644-1FS 209E ClassMax particles ≥0.5 µm / m³Typical ACPHTypical Application
ISO 5Class 1003,520240–480 (unidirectional)Aseptic filling, critical exposed product zones
ISO 6Class 1,00035,200150–240Sterile support, high-risk compounding
ISO 7Class 10,000352,00060–90Core manufacturing and processing suites
ISO 8Class 100,0003,520,00020–40Secondary operations, packing, material airlocks

Indicative industry values. Final ACPH is derived from heat load, occupancy and process during design qualification.

Design parameters we control

  • Air changes per hour (ACPH) per room
  • Pressure cascade, typically 10–15 Pa steps
  • Temperature and relative humidity setpoints and tolerances
  • Staged filtration: pre → fine → HEPA H13 / H14
  • Airflow patterns and recovery time
  • Contamination and cross-contamination control
Thermally insulated ducting network installed in a ceiling grid
Air DistributionInsulated ducting network
How We Deliver

A ten-stage execution methodology

A structured, validation-ready delivery process that keeps your project audit-proof from day one.

Procurement

Vendor and material finalisation against approved specifications.

Design Qualification

URS translated into an approved, auditable design basis.

Detailed Engineering

Drawings, BOQs, schematics and interface coordination.

Validation Planning

Protocols and acceptance criteria agreed before fabrication.

Equipment Construction

Factory manufacturing of panels, doors, AHUs and equipment.

Factory Testing

FAT completed and signed off before dispatch to site.

Shipping & Installation

Site erection executed by our own installation teams.

Site Testing

SAT, IQ and OQ execution with your quality team.

Documentation

Complete validation dossier compiled and handed over.

Training & Commissioning

Operator training, handover and 24×7 ongoing support.

Start the Conversation

Tell us what you're building.

Share your process, area and target classification, and we'll come back with a design approach and a detailed techno-commercial proposal.